Overview Southwire's SIMpull designed for easier pulling, resulting in easier installation. *Data provided on this page is subject to change based on different manufacturers variances. 250 1000 THIS ITEM IS CURRENTLY UNAVAILABLE Please check later - it'll be ready for purchase again soon. Southwire 28828228 100 12/2 with ground Romex brand SIMpull residential indoor electricial wire type NM-B Yellow. /rebates/2fp2fSouthwire-200-ft-12-2-Yellow-Solid-Romex-SIMpull-NM-B-PCS-Duo-Cable-679628012f312600203&. For Southwire® Romex® SIMpull® 12/2 with ground cable, the major diameter is listed at 410 mils. Soft, bare copper solid per ASTM B3 and stranded per ASTM B3 and B8ģ0 mil color coded PVC sheath rated 90☌ is applied over the completed assembly 12-2-2 NM-B Cable Specifications*: Yellow jacket: Romex® 12/3 and 12/2 Orange jacket: Romex® 10/3 and 10/2 Gray jacket: Larger sizes between 8 AWG and 2 AWG Romex® meets various standards, making it suitable for many uses. To calculate conduit fill for cables, you treat each cable as a single conductor and calculate the fill based on the major diameter of the cable (looked up from manufacturer documentation). Solid annealed soft bare copper per ASTM B3.Ĭolor coded polyvinyl chloride (PVC) compound with a nylon covering meeting the required thickness of Type THHN. UL 83: Thermoplastic Insulated Wires and Cablesįederal Specification A-A-59544 and requirements of the NEC. Meets or exceeds all applicable ASTM specifications NM-B cables are LEAD FREE and RoHS compliant.Īlso Known As: NM-B - 12 AWG, NM-B - Type, Building Wire, Wire, Cables, Cords, Romex ® It may be fished through masonry or tile walls, where not exposed or subject to excessive moisture or dampness. Romex Wire McMaster-Carr (630) 833-0300 Email Us Clear All Industry Designation Show NM- B Number of Wires 2 3 Wire Gauge 14 12 10 Outer Insulation Color White Yellow Orange Wire Type Solid System of Measurement Inch Length 10 ft. NM-B is rated at 600 volts and although it is rated at a conductor temperature of 90☌ dry, its ampacity is limited to 60☌ according to the NEC 2008 and NEC 2011. MG Store Home: 02 San Antonio Retail 12/2 NM-B Wire with Ground Romex 250 Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Its applications are outlined in NEC 2008 and NEC 2011 Article 334. Non-metallic sheathed NM-B cable is used in normally dry installations in residential wiring, as branch circuits for outlets, lighting and other residential loads. Color Code: Black, white, red, white with red stripe.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |